{"id":844,"date":"2012-05-16T11:48:52","date_gmt":"2012-05-16T18:48:52","guid":{"rendered":"http:\/\/beltegrity.com\/?page_id=844"},"modified":"2012-08-24T11:29:00","modified_gmt":"2012-08-24T18:29:00","slug":"abstract-equipping-well-no-144","status":"publish","type":"page","link":"https:\/\/kriegerandstewart.com\/?page_id=844","title":{"rendered":"Abstract &#8211; Equipping Well No.144"},"content":{"rendered":"<h2>Equipping Well No. 144<\/h2>\n<p><strong>Client:<\/strong>\u00a0 Victorville Water District<br \/>\n<strong>Location:<\/strong>\u00a0 Victorville, California<br \/>\n<strong>Construction Cost:<\/strong>\u00a0 $2M<\/p>\n\r\n<div class=\"column grid_4\">\r\n\r\n&nbsp;\r\n<h3><span style=\"color: #0033cc;\">Project Features:<\/span><\/h3>\r\n<ul>\r\n\t<li><span style=\"color: #0033cc;\">1,250 hp Vertical Turbine Pumping Unit <\/span>\r\n<span style=\"color: #0033cc;\">with VFD<\/span><\/li>\r\n\t<li><span style=\"color: #0033cc;\">Sodium Hypochlorite and Future Aqueous Ammonia Disinfection<strong><\/strong><\/span><\/li>\r\n\t<li><span style=\"color: #0033cc;\">SCE Utility Service Coordination Required<strong><\/strong><\/span><\/li>\r\n\t<li><span style=\"color: #0033cc;\">Masonry Block Building with Concrete Roof<strong><\/strong><\/span><\/li>\r\n\t<li><span style=\"color: #0033cc;\">Separate Air Conditioned Electrical Equipment Room<strong><\/strong><\/span><\/li>\r\n\t<li><span style=\"color: #0033cc;\">Site and Building Security Systems<strong><\/strong><\/span><\/li>\r\n\t<li><span style=\"color: #0033cc;\">SCADA System<\/span><\/li>\r\n<\/ul>\r\n<\/div><!-- .column (end) -->\r\n<p style=\"text-align: center;\"><div class=\"column grid_8 last\"><\/p>\r\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1673\" title=\"Equipping Well No. 144\" src=\"https:\/\/kriegerandstewart.com\/wp-content\/uploads\/2012\/08\/Equipping_Well_No144.jpg\" alt=\"Equipping Well No. 144\" width=\"448\" height=\"344\" srcset=\"https:\/\/kriegerandstewart.com\/wp-content\/uploads\/2012\/08\/Equipping_Well_No144.jpg 448w, https:\/\/kriegerandstewart.com\/wp-content\/uploads\/2012\/08\/Equipping_Well_No144-300x230.jpg 300w, https:\/\/kriegerandstewart.com\/wp-content\/uploads\/2012\/08\/Equipping_Well_No144-195x149.jpg 195w\" sizes=\"auto, (max-width: 448px) 100vw, 448px\" \/><\/p>\r\n<p style=\"text-align: center;\">\u00a0<\/div><!-- .column (end) -->\r\n<div class=\"clear\"><\/div>\r\n<\/p>\n<h3>Description:<\/h3>\n<p>Equipping Well No. 144 project consisted of equipping Well No. 144 with a 1,250\u00a0hp deep well vertical turbine pumping unit within a masonry block building, variable frequency drive (VFD) unit (located within a separate air conditioned electrical equipment room of the masonry block building), sodium hypochlorite disinfection and future aqueous ammonia disinfection equipment (each within separate rooms of the masonry block building), discharge piping, blowoff piping and appurtenances, and electrical service facilities.\u00a0 Site improvements included grading within an existing site block wall, Class II base, and site and building security systems.<\/p>\n<h3>Services Provided:<\/h3>\n<p>Krieger &amp; Stewart provided design engineering services, including preliminary design, equipment selection, design survey, system hydraulic modeling, final design, and contract document preparation for construction.\u00a0 Krieger\u00a0&amp;\u00a0Stewart also provided limited construction phase services, which included review of pumping unit and electrical equipment submittals; electrical inspection; and facility startup, performance testing, and acceptance.\u00a0 Krieger &amp; Stewart provided all of the civil, structural, mechanical, architectural, electrical, and instrumentation design.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Equipping Well No. 144 Client:\u00a0 Victorville Water District Location:\u00a0 Victorville, California Construction Cost:\u00a0 $2M Description: Equipping Well No. 144 project consisted of equipping Well No. 144 with a 1,250\u00a0hp deep well vertical turbine pumping unit within a masonry block building, variable frequency drive (VFD) unit (located within a separate air conditioned electrical equipment room of [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"open","ping_status":"open","template":"","meta":{"footnotes":""},"class_list":["post-844","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/kriegerandstewart.com\/index.php?rest_route=\/wp\/v2\/pages\/844","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/kriegerandstewart.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/kriegerandstewart.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/kriegerandstewart.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/kriegerandstewart.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=844"}],"version-history":[{"count":4,"href":"https:\/\/kriegerandstewart.com\/index.php?rest_route=\/wp\/v2\/pages\/844\/revisions"}],"predecessor-version":[{"id":1914,"href":"https:\/\/kriegerandstewart.com\/index.php?rest_route=\/wp\/v2\/pages\/844\/revisions\/1914"}],"wp:attachment":[{"href":"https:\/\/kriegerandstewart.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=844"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}